INSTALLATION MANUAL MOTOR FOR SWING LEAF GATES SWING-3000/5000

Strany 2 - Contents

COMPONENTS SET № Component Quantity 1 Opener 2 2 Front bracket 2 3 Rear joint 2 4 Rear bracket 2 5 Fixing set 1 6

Strany 3

ASSEMBLY Preliminary checks To ensure trouble-free operation, make sure that the gate (whether existing or yet to be installed) has the following

Strany 4 - TOOLS AND MATERIALS

1.2 - Basic Cable Layout THIS DIAGRAM DETAILS THE BASIC CABLE LAYOUT FOR A PAIR OF MOTORS. THE POWER SUPPLY TO THE CONTROL PANEL SHOULD BE LIVE

Strany 5

1.3 - Low Voltage Cable Layout ALL CAME ACCESSORIES CAN BE WIRED 0.2m STRANDED CABLE (BUGLAR ALARM TYPE). THE TUNED ANTENNA SHOULD BE WIRED WITH

Strany 6 - WARNINGS FOR THE INSTALLER

INSTALLATION - To ensure you work in safe conditions, we advise you to install the operator while keeping the door fully closed. - Use all the s

Strany 7 - FUNCTIONS

1.5 - Attaching the Rear Bracket THE REAR BRACKET IS EQUIPPED WITH ADDITIONAL HOLES TO MAKE INSTALLATION OF THE GATE MOTOR EASIER, OR TO CHANGE

Strany 8 - TECHNICAL SPECIFICATIONS

1.6 - Attaching the Front Bracket WITH THE GATE IN THE FULLY CLOSED POSITION WELD THE FRONT BRACKET TO THE FIXING PLATE THEN ATTACH IT TO THE GA

Strany 9 - Dimensions

2.3 - Installing the Motors WITH THE COVERS REMOVED INSTALL THE MOTOR ON THE TWO BRACKETS AND SECURE THE MOTOR WITH THE NUTS AND BOLTS PROVIDED.

Strany 10 - COMPONENTS SET

2.4 - Adjusting the Open Stop Microswitch MANUALLY RELEASE THE REDUCTION GEAR BY INSERTING THE RELEASE KEY AND TURNING IT 180. MOVE THE GAT

Strany 11 - ASSEMBLY

2.5 - Wiring the Motors ENSURE BOTH MOTORS ARE ADEQUATELY EARTHED. Fitting the Control Panel in the Casing Securely fasten the control panel P

Strany 12

Contents INSTALLATION MANUAL...

Strany 13

CONTROL BOARD Technical specifications Power supply 230 V~ ( +6% -10%) - 50 Hz Absorbed power 10 W Motor max. load 800 W Accessories max. lo

Strany 14 - INSTALLATION

Led OP_A TOTALLY OPEN LED Led OP_B LED: LED: OPEN LEAF 1 / CLOSE Led STOP LED LED STOP Led FSWCL LED: LED: CLOSING SAFETY DEVICES Led FSW

Strany 15

Electrical connections IMPORTANT: Before attempting any work on the board (connections, maintenance), always cut off power.

Strany 16

Terminal board J1 - Accessories OPEN A - "Total Opening" command (N.O.): any pulse generator (push-button, detector, etc.) which, by cl

Strany 17

PROGRAMMING Leaf l and 2 force By using microswitches SW1, SW2 and SW3, the force (and thus anticrushing safety) of the operator connected to lea

Strany 18

Function logic The automated system's function logic can be selected with microswitches SW7, SW8, SW9 and SW10. By selecting an automatic lo

Strany 19

- SIMPLE LEARNING: Check if the leaves are closed, and then press F push-button for one second: DL10 LED begins flashing and the leaves begin th

Strany 20 - CONTROL BOARD

Radio controls encoding Connection of DHRE-2 reciever External receiver DHRE-2 is meant for receiving radio remote control signal with 433 MHz

Strany 21

START UP LED CHECK The table below shows the status of the LEDs in relation to to the status of the inputs. Note the following: Led lighted = clo

Strany 22 - Electrical connections

TROUBLESHOOTING To avoid being electrocuted, only a professional technician is allowed to touch the wires and components on the main panel. PROB

Strany 23

GENERAL SAFETY INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE • For an efficient and safe automated door, correctly observe the installation proced

Strany 25

IMPORTANT! DANGER OF CRUSHING. If the power cable of operator SWING is damaged, it must be replaced by qualified personnel, using a new cable of

Strany 26

Material required for installing the SWING operator and the relevant accessories (if present): Cable 2x0,5 mm2 (emitting photocells, pulse gener

Strany 27 - Radio controls encoding

WARNINGS FOR THE INSTALLER ATTENTION! To ensure the safety of people, it is important that you read all the following instructions. Incorrect in

Strany 28 - MAINTENANCE

20) The installer shall supply all information concerning manual operation of the system in case of an emergency, and shall hand over to the use

Strany 29 - TROUBLESHOOTING

TECHNICAL SPECIFICATIONS Swing-5000 Leaf width, m Leaf weight, kg 2.00 1000 2.50 800 3.00 600 4.00 500 5.00 400 Model Sw

Strany 30

Dimensions 1. Cover 2. Front bracket 3. Rear joint 4. Rear bracket 5. Release unit 6. Worm gear